CGWA/RGI-accredited Ground Water Professional · Led by former CGWB Chairmen · RGI-certified Water Auditor +91 98110 25130 · info@hydrogeosolutions.in
Hydro Geo Solutions LLP Innovate, Conserve, Sustain
Home / Services / CGWA NOC & Impact Assessment
Industry · Infrastructure

CGWA NOC consultants: NOC applications and Impact Assessment Reports

As a CGWA / RGI accredited Ground Water Professional institution, we prepare the technical case for groundwater abstraction and see the application through to the NOC, then keep you compliant.

Industries and infrastructure projects that draw groundwater need a No Objection Certificate from the Central Ground Water Authority, or from the state authority where a state regulates groundwater itself. The application stands on the Impact Assessment Report: what the aquifer can sustain, what your pumping will do to water levels around the site, and how you will offset it. As a CGWA/RGI-accredited Ground Water Professional institution, we prepare these reports with or without groundwater modelling, depending on the volume and the stress in your block.

What you get

  • Impact Assessment Report (IAR) with or without groundwater flow modelling
  • Resource assessment following the GEC-2015 methodology and the latest CGWB block data
  • Water audit and site water balance
  • Online application filing and replies to queries
  • NOC renewal, including review of compliance with existing conditions
  • Piezometer construction, flow meters, recharge structures and monitoring reports

Who it is for

Manufacturing plants, beverage and food units, pharma, textiles, distilleries and ethanol plants, power plants, townships and real estate.

Common questions

Which authority issues the NOC?

CGWA under the Ministry of Jal Shakti, except in states and union territories that regulate groundwater through their own authority. We confirm the right authority at the scope call.

When is groundwater modelling required?

It depends on the abstraction volume, the block category and the authority's current guidelines. We tell you at the start whether your case needs an IAR with modelling, so there is no surprise at the query stage.

Do you handle renewals and show-cause notices?

Yes. Renewals turn on compliance with the conditions of the existing NOC. We audit that compliance, fix gaps on the ground, and prepare the technical reply.

Lower charges, fewer surprises

Four things that change what your NOC costs

50% rebate for recharge

Existing industries, infrastructure and mining projects that built the recharge structures required by their NOC are eligible for a 50% rebate on groundwater abstraction or restoration charges, subject to satisfactory performance and verification. We design the structures, document their performance and claim the rebate at renewal.

Saline groundwater is exempt

Industries, infrastructure dewatering and mines that draw saline groundwater are exempt from abstraction charges, even in over-exploited areas. Showing fresh water as saline attracts a Rs 2 lakh penalty, so we test and classify the water properly and prepare the effluent disposal plan the guidelines require.

Water audit and 20% reduction

Industries drawing more than 100 m³/day must have a water audit every two years by a certified auditor and cut groundwater use by at least 20% over three years. Our certified auditor prepares the audit and a reduction plan you can show at renewal. Water audits →

Dewatering and settlement risk

Basements, tunnels and underpasses need a dewatering NOC, and lowering the water table can make nearby ground settle. We estimate inflow, model the drawdown within 5 km and check settlement risk to adjacent structures, with monitoring limits during construction.

Meters, DWLRs and telemetry for NOC compliance → · Received a CGWA notice? →

Have a water question at your site?

Tell us about your site and what you need to know. A senior hydrogeologist replies within one working day.

WhatsApp